Next generation freeze protection
[Q]Core integrates Dragon Jacket pipe insulation and heat trace to keep water and sewer lines from freezing. Each component contains a heating element and installs like the rest of Dragon Jacket’s pipe insulation: wrap it around the pipe, secure it with banding and plug it in.
Insulation and heat trace in one step
- Supply voltage
- 120 V AC
- Temperature range
- −40°F to 250°F
- Connector rating
- IP68
For water and sewer mains that experience no or reduced flow, insulation alone is not sufficient when temperatures drop below freezing. An effective insulation system significantly reduces heat loss but cannot prevent all of it, and during prolonged periods of stagnation, supplemental heat is required to offset what passes through the insulation. Traditionally, this means three separate projects on a single line: heat trace cable run by a licensed electrician, insulation over top of it, and a protective layer on top of that.
[Q]Core puts the heating element inside the insulation. Each component arrives with the heating element already inside and a lead with a connector. It installs by wrapping the component around the pipe, banding it in place and plugging it into the supply harness. The insulation, heat and jacketing are installed in a single component.
- No separate heat trace cable, jacketing or insulation trade
- Runs on 120 V and installs without an electrician
- Easily removed and re-installed for maintenance
![[Q]Core on chemical unloading lines in the snow at PQ Corporation in Chicago](https://www.dragonjacket.com/wp-content/uploads/2025/07/IMG_2810-scaled.jpg)
![[Q]Core on HDPE water and sewer mains hung beneath a bridge deck in Mountain Green, Utah](https://www.dragonjacket.com/wp-content/uploads/2026/11/WasatchQCore3-1-scaled.jpeg)
![[Q]Core lines running between tanks at PQ Corporation](https://www.dragonjacket.com/wp-content/uploads/2025/07/IMG_2803-scaled.jpg)
Built for the most exposed lines
A frozen line can burst, interrupt service and require emergency repairs in the harshest conditions of the year. [Q]Core is designed for the lines where freezing is most likely.
Bridge crossings
Water and sewer mains hung beneath bridge decks, open to wind and cold on every side.
Exposed mains
Water mains and service lines that run above grade, along structures or through unheated spaces.
Sewer force mains
Pressurized lines that sit full and still between pump cycles.
Pump and lift stations
Exposed piping at pump stations, lift stations and treatment plants.
Intake and raw water lines
Lines that run outdoors before they reach the treatment building.
Chemical feed and unloading lines
Lines that sit full between deliveries and doses, where a frozen line stops the process.
One component, no specialty trades
![[Q]Core banded on a water main hung from bridge hangers in Mountain Green, Utah](https://www.dragonjacket.com/wp-content/uploads/2026/11/WasatchQCore4-1-scaled.jpeg)
![[Q]Core on an unloading line beside a tank at PQ Corporation](https://www.dragonjacket.com/wp-content/uploads/2025/07/DJI_PQ_After-1536x1152.jpg)
Each [Q]Core component is Dragon Jacket pipe insulation with a heating element built in. The heat output is sized to the line, so the pipe stays above freezing at the coldest temperature the site will see.
Wrap and band
Set the component over the pipe and band it shut, the same as all Dragon Jacket.
Plug into the harness
Each component’s lead plugs into a supply harness that runs along the line.
Plug in the harness
The harness plugs into a 120 V receptacle.
[Q]Core in the field
![[Q]Core on an unloading line at PQ Corporation in winter](https://www.dragonjacket.com/wp-content/uploads/2025/07/IMG_2801-scaled.jpg)
Chemical unloading lines
Fiberglass blankets over conventional heat trace kept getting crushed at ground level, and crews used steam to keep the valves thawed. [Q]Core replaced both the insulation and the heat trace, and no steam was needed on the lines all winter. The project qualified for a North Shore Gas subsidy covering about half its cost.
See the project →![[Q]Core on a water main beneath a bridge deck in Mountain Green, Utah](https://www.dragonjacket.com/wp-content/uploads/2026/11/WasatchQCore1-1.jpeg)
Water and sewer bridge crossing
A 10″ HDPE water main and a 4″ HDPE sewer main hang side by side beneath a bridge deck. [Q]Core went on 177 ft of each line, insulated and heat traced in one step by the general contractor’s crew.
See the project →Specifications & documents
- Supply voltage
- 120 V AC
- Temperature range
- −40°F to 250°F (−40°C to 121°C)
- Circuit protection
- GFCI and AFCI protection recommended
- Connector rating
- IP68
- Heat output
- Sized to application
- Insulation
- Dragon Jacket closed-cell polyisocyanurate core, encapsulated in polyurea
- R-value per inch
- 6.25
Request more information
Send us the pipe size and material, the length of the line, the insulation thickness if it’s specified, and the coldest design temperature at the site. We’ll size [Q]Core for the line and send a quote. Fill out the form below, or ask a product question first.